I/O SystemsX20
X20BC0087-10Fieldbus: Modbus/TCP
📦3-4 wekenUitgefaseerd
Fieldbus
1
X2X Link
500 μs
Transfer Rate
10/100
Dit product is uitgefaseerd
Dit artikel is niet meer leverbaar en kan niet worden besteld. We tonen het zodat de productinformatie vindbaar blijft. Neem contact met ons op voor een vervangend of compatibel alternatief.
Zakelijk klant? Vraag een offerte aan of log in voor uw prijs.
Omschrijving
- Fieldbus: Modbus/TCP, Modbus/UDPI/O configuration via the fieldbus
- DHCP-capable
- Bootp-capable
- Integrated double switch for efficient cabling
- Configurable I/O cycle (0.5 to 4 ms)Response time: <1 to 8 ms (depending on the load on the integrated switch)Validity check for command sequences before execution
- Producer mode Established in 1979, the Modbus protocol has approved the use of Ethernet with both Modbus TCP and Modbus/UDP. Today, Modbus TCP is an open Int
- Fieldbus: Modbus/TCP, Modbus/UDPI/O configuration via the fieldbus
- DHCP-capable
- Bootp-capable
- Integrated double switch for efficient cabling
- Configurable I/O cycle (0.5 to 4 ms)Response time: <1 to 8 ms (depending on the load on the integrated switch)Validity check for command sequences before execution
- Producer mode Established in 1979, the Modbus protocol has approved the use of Ethernet with both Modbus TCP and Modbus/UDP. Today, Modbus TCP is an open Internet draft standard introduced by Schneider Automation to the Internet Engineering Task Force (IETF), the organization responsible for Internet standardization. The Modbus services and object model have been preserved since the original version and left unchanged for use with the TCP/IP transmission medium. Modbus/UDP differs from Modbus TCP in that it uses connectionless communication via UDP/IP. The advantages of faster and easier communication with UDP/IP also brings with it the disadvantage of requiring error detection and correction in the application layer.This bus controller makes it possible to connect X2X Link I/O nodes to Modbus via Ethernet. The bus controller can be operated on B&R controllers through the use of Automation Studio or on third-party systems with Modbus TCP or -UDP master functionality.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description). All other function models are supported when configured accordingly in Automation Studio V4.3 or later. Automation Studio kann kostenlos von der B&R Webseite www.br-automation.com heruntergeladen werden. Die Evaluierungslizenz darf unentgeltlich zur Erstellung vollständiger Konfigurationen der Feldbus Bus Controller benützt werden.
Productinformatie
- Serie
- X20